Scalar i6000 Installation Guide
89
Removing and Replacing the IEX Card
If you are adding one or more expansion modules to an existing eight-module library, each expansion
module you are adding must contain an IEX2 card. The IEX2 card is identified by a red sticker. If an
expansion module you are adding contains an earlier version of the IEX card, you must remove the earlier
version and replace it with an IEX2 card.
Removing the IEX Board
Required Tools: None
FRU ID: 105 (IEX board)
1
If the library is not shut down, shut down the library.
For more information, see
2
Open the service door.
3
Attach the ESD strap to your wrist and to an unpainted surface inside the door.
4
Unscrew the thumbscrew and remove the LBX/IEX cover plate.
CAUTION
Only use this procedure if you are preparing to install expansion modules
to an existing eight-module library.
Note
New IEX2 cards are identified by red stickers. Earlier IEX card versions
have no stickers.
thumbscrew
Summary of Contents for Scalar i6000
Page 20: ...8 About This Guide and Your Product...
Page 38: ...26 Installing a Stand Alone Control Module...
Page 104: ...92 Installing a Multi Module Library...
Page 156: ...144 Installing Cartridges...
Page 164: ...152 Setting up Your Library for Access...
Page 242: ...230 Configuring the Library...
Page 304: ...292 Adding Optional Hardware eight 2 5 mm screws...
Page 318: ...306 Adding Optional Hardware...
Page 336: ...324 Installation Testing and Verification Figure 35 Example Test Log Output...
Page 356: ...344 Testing and Calibrating the Digital Level...
Page 362: ...350 LBX Board and Terminator...
Page 380: ...368 Glossary...
Page 384: ...372 Index...