PE6000 User Manual Description of Function Codes
183
U0-28
Communication setting value
Display Range
-100.00%–100.00%
It displays the data written by means of the communication address 0x1000.
U0-30
Main frequency X
Display Range
0.00–320.00 Hz
0.0–3200.0 Hz
It displays the setting of main frequency X.
•
If P0-22 (Frequency reference resolution) is 1, the display range is -3200.0–3200.0 Hz.
•
If P0-22 (Frequency reference resolution) is 2, the display range is -320.00–320.00 Hz.
U0-31
Auxiliary frequency Y
Display Range
0.00–320.00 Hz
0.0–3200.0 Hz
It displays the setting of auxiliary frequency Y.
Ÿ
If P0-22 (frequency reference resolution) is 1, the display range is -3200.0–3200.0 Hz.
Ÿ
If P0-22 (frequency reference resolution) is 2, the display range is -320.00–320.00 Hz.
U0-35
Target torque
Display Range
-200.0%–200.0%
It displays the setting of auxiliary frequency Y.
U0-37
Power factor angle
Display Range
It displays the current power factor angle.
U0-39
Target voltage upon V/F
separation
Display Range
0 V to rated motor voltage
U0-40
Output voltage upon V/F
separation
Display Range
0 V to rated motor voltage
They display the target output voltage and current actual output voltage in the V/F separation
state. For V/F separation, see the descriptions of group F3.
U0-41
DI state visual display
Display Range
It displays the DI state visually and the display format is shown in the following figure. Figure
Display format of the DI state