Description of Function Codes PE6000 User Manual
176
Source
Actual data
Correspondent
sending data
Output Torque
-200%-200%
-100%-100%
Running
frequency
-maximum
frequency to
maximum
frequency
Setting
frequency
Feedback
speed
A8-03
Usage of data received by slave
Default
0
Setting Range
0: Torque setting
1: Frequency setting
It is used to determine whether the slave uses data received from the master for torque setting
or frequency setting. This function can be used only when the frequency source or torque source
must be communication setting.
When the AC drive is a slave in point-point communication and receives data for torque setting,
100.00% of the received data corresponds to 200.0% of torque setting, unrelated to A0-03. If zero
offset of the slave is 0.00% and the gain is 1.00, it means that the slave directly takes the output
torque of the master as the target torque.
When the AC drive is a slave in point-point communication and receives data for frequency
setting, 100.00% of the received data corresponds to the value of P0-10 (Maximum frequency).
For example, to balance the load, do the following settings.
Master
A0-00 = 0: Speed control
A8-00 = 1: Point-point communication enabled
A8-01 = 0: Master in point-point communication
A8-02 = 0: Data source from master being output torque
Slave
A0-00 = 1: Torque control
A8-00 = 1: Point-point communication enabled
A8-01 = 1: Slave in point-point communication
A8-03 = 0: Slave receiving data for torque setting
A0-01 = 5: Torque source in torque control set to communication setting