PE6000 User Manual Function Code Tables
57
Function
Code
Parameter Name
Setting Range
Default
Property
P6-05
Startup DC braking
current/ Pre-excited
current
0%–100%
0%
★
P6-06
Startup DC braking
time/ Pre-excited
time
0.0–100.0s
0.0s
★
P6-07
Acceleration/Deceler
ation mode
0: Linear acceleration/ deceleration
1: S-curve acceleration/ deceleration A
2: S-curve acceleration/
deceleration B
0
★
P6-08
Time proportion of
S-curve start
segment
0.0% to (100.0% – P6-09)
30.0%
★
P6-09
Time proportion of
S-curve end
segment
0.0% to (100.0% – P6-08)
30.0%
★
P6-10
Stop mode
0: Decelerate to stop 1: Coast to stop
0
☆
P6-11
Initial frequency of
stop DC braking
0.00 Hz to maximum frequency
0.00 Hz
☆
P6-12
Waiting time of stop
DC braking
0.0–100.0s
0.0s
☆
P6-13
Stop DC braking
current
0%–100%
0%
☆
P6-14
Stop DC braking time
0.0–100.0s
0.0s
☆
P6-15
Brake use ratio
0%–100%
100%
☆