Function Code Tables PE6000 User Manual
50
Function
Code
Parameter Name
Setting Range
Default
Property
Group P3: V/F Control Parameters
P3-00
V/F curve setting
0: Linear V/F
1: Multi-point V/F
2: Square V/F
3: 1.2-power V/F
4: 1.4-power V/F
6: 1.6-power V/F
8: 1.8-power V/F
9: Reserved
10: V/F complete separation
11: V/F half separation
0
★
P3-01
Torque boost
0.0% (fixed torque boost)
0.1%–30.0%
Model
dependent
☆
P3-02
Cut-off frequency
of torque boost
0.00 Hz to maximum output
frequency
50.00 Hz
★
P3-03
Multi-point V/F
frequency 1 (F1)
0.00 Hz to P3-05
0.00 Hz
★
P3-04
Multi-point V/F
voltage 1 (V1)
0.0%–100.0%
0.0%
★
P3-05
Multi-point V/F
frequency 2 (F2)
P3-03 to P3-07
0.00 Hz
★
P3-06
Multi-point V/F
voltage 2 (V2)
0.0%–100.0%
0.0%
★
P3-07
Multi-point V/F
frequency 3 (F3)
F3-05 to rated motor frequency
(P1-04)
0.00 Hz
★
P3-08
Multi-point V/F
voltage 3 (V3)
0.0%–100.0%
0.0%
★
P3-09
V/F slip
compensation gain
0%–200.0%
0.0%
☆
P3-10
V/F over-excitation
gain
0–200
64
☆
P3-11
V/F oscillation
suppression gain
0–100
Model
dependent
☆