Description of Function Codes PE6000 User Manual
104
Value
Function
Description
49
Deceleration DC braking
When this terminal becomes ON, the AC drive
decelerates to the initial frequency of stop DC braking
and then switches over to DC braking state.
50
Clear the current running
time
When this terminal becomes ON, the AC drive's current
running time is cleared. This function must be
supported by P8-42 and P8-53.
The four multi-reference terminals have 16 state combinations, corresponding to 16 reference
values, as listed in the following table.
The following table states combinations of the four multi-reference terminals
K4
K3
K2
K1
Reference Setting
Corresponding Parameter
OFF
OFF
OFF
OFF
Reference 0
PC-00
OFF
OFF
OFF
ON
Reference 1
PC-01
OFF
OFF
ON
OFF
Reference 2
PC-02
OFF
OFF
ON
ON
Reference 3
PC-03
OFF
ON
OFF
OFF
Reference 4
PC-04
OFF
ON
OFF
ON
Reference 5
PC-05
OFF
ON
ON
OFF
Reference 6
PC-06
OFF
ON
ON
ON
Reference 7
PC-07
ON
OFF
OFF
OFF
Reference 8
PC-08
ON
OFF
OFF
ON
Reference 9
PC-09
ON
OFF
ON
OFF
Reference 10
PC-10
ON
OFF
ON
ON
Reference 11
PC-11
ON
ON
OFF
OFF
Reference 12
PC-12
ON
ON
OFF
ON
Reference 13
PC-13
ON
ON
ON
OFF
Reference 14
PC-14
ON
ON
ON
ON
Reference 15
PC-15
If the frequency source is multi-reference, the value 100% of PC-00 to PC-15 corresponds to
the value of P0-10 (Maximum frequency).
Besides the multi-speed function, the multi-reference can be also used as the PID setting
source or the voltage source for V/F separation, satisfying the requirement on switchover of