PE6000 User Manual Description of Function Codes
165
2. Clear records
If PP-01 is set to 2, the fault records, accumulative running time (P7-09), accumulative
power-on time (P7-13) and accumulative power consumption (P7-14) are cleared.
3. Back up current user parameters
Back up current user parameters and the current parameter settings are backed up, helping
you to restore the setting if incorrect parameter setting is performed.
4. Restore user backup parameters
If PP-01 is set to 501, the previous backup user parameters are restored.
PP-02
AC drive parameter display property
Default
11
Setting Range
Unit's digit
Group U display selection
0
Not display
1
Display
Ten's digit
Group A display selection
0
Not display
1
Display
Name
Description
AC drive parameter display
Display function codes of the AC drive in sequence of P0 to
PF, A0 to AF and U0 to UF.
User-defined parameter
display
Display a maximum of 32 user-defined parameters included
in group PE.
User-modified parameter
display
Display the parameters that are modified.
The PE6000 provides display of two types of individualized parameters: user-defined
parameters and user-modified parameters.
•
You-defined parameters are included in group PE. You can add a maximum of 32 parameters,
convenient for commissioning.
In user-defined parameter mode, symbol "u" is added before the function code.
For example, P1-00 is displayed as uP1-00.You-modified parameters are grouped together,
convenient for on-site troubleshooting.
In you-modified parameter mode, symbol "c" is added before the function code.
For example, P1-00 is displayed as cP1-00.