PE6000 User Manual Description of Function Codes
139
P8-38
Any current reaching 1
Default
100.0%
Setting Range
0.0%–300.0% (rated motor current)
P8-39
Any current reaching 1 amplitude
Default
0.0%
Setting Range
0.0%–300.0% (rated motor current)
P8-40
Any current reaching 2
Default
100.0%
Setting Range
0.0%–300.0% (rated motor current)
P8-41
Any current reaching 2 amplitude
Default
0.0%
Setting Range
0.0%–300.0% (rated motor current)
If the output current of the AC drive is within the positive and negative amplitudes of any current
reaching detection value, the corresponding DO becomes ON.
The PE6000 provides two groups of any current reaching detection parameters, including
current detection value and detection amplitudes, as shown in the following figure.
Figure 5-23 Any current reaching detection
P8-36
P8-37