PE6000 User Manual Description of Function Codes
107
Function
Code
Parameter Name
Value
Function Description
P4-11
Terminal command mode
1
Two-line 2
P4-00
DI1 function selection
1
RUN enabled
P4-01
DI2 function selection
2
Forward or reverse
direction
Figure 5-7 Setting of two-line mode 2
As shown in the preceding figure, if K1 is ON, the AC drive instructs forward rotation when K2
is OFF, and instructs reverse rotation when K2 is ON. If K1 is OFF, the AC drive stops.
•
2: Three-line mode 1
In this mode, DI3 is RUN enabled terminal, and the direction is decided by DI1 and DI2. The
parameters are set as below:
Function
Code
Parameter Name
Value
Function Description
P4-11
Terminal command mode
2
Three-line 1
P4-00
DI1 function selection
1
Forward RUN (FWD)
P4-01
DI2 function selection
2
Reverse RUN (REV)
P4-02
DI3 function selection
3
Three-line control
PE6000