P0-19
Acceleration/Decelera
tion time unit
0:1s
1: 0.1s
2: 0.01s
1
★
P0-21
Frequency offset of
auxiliary frequency
source for X and Y
operation
0.00 Hz to maximum frequency
(P0-10)
0.00 Hz
☆
P0-22
Frequency reference
resolution
1: 0.1 Hz
2: 0.01 Hz
2
★
P0-23
Retentive of digital
setting frequency
upon power failure
0: Not retentive
1: Retentive
0
☆
P0-24
Output selection by
frequency 0 Hz
0: Output
1: No output
0
☆
P0-25
Acceleration/Decelera
tion time base
frequency
0: Maximum frequency(P0-10)
1: Set frequency
2: 100 Hz
0
★
P0-26
Base frequency for
UP/ DOWN
modification during
running
0: Running frequency
1: Set frequency
0
★
P0-27
Binding command
source to frequency
source
Unit's digit (Binding operation
panel command to frequency
source)
0000
☆
0: No binding
1: Frequency source by digital
setting
2: AI1
3: AI2
4: Keyboard potentiometer
5: Pulse setting(DI5)
6: Multi-reference
7: Simple PLC
8: PID
9: Communication setting
Ten's digit (Binding terminal
command to frequency source)
Hundred's digit (Binding
communication command to
frequency source)
Thousand’s digit (Binding
automatic operation to
frequency source)