Operation, Display and Application Examples PE6000 User Manual
16
Hz: unit of frequency
A: unit of current
V: unit of voltage
RPM (HZ+A): unit of rotational speed
%( A+V): percentage
3)
Data Display
The 5-digit LED display is able to display the set frequency, output frequency, monitoring data
and fault codes.
4)
Description of keys on the operation panel
Table 3-1 Description of keys on the operation panel
Key
Name
Function
PRG
Programming
Enter or exit Level I menu.
ENTER
Confirm
Enter the menu interfaces level by level, and
confirm the parameter setting.
Increment
Increase data or function code
Decrement
Decrease data or function code
Shift
Select the displayed parameters in turn in the
stop or running state, and select the digit to be
modified when modifying parameters.
RUN
RUN
Start the AC drive in the operation panel
control mode.
STOP/RES
Stop/Reset
Stop the AC drive when it is in the running
state and perform the reset operation when it
is in the fault state. The functions of this key
are restricted in P7-02.
MF.K
Multifunction
Perform function switchover according to the
setting of F7-01.
QUICK
Menu mode selection
Perform switchover between menu modes
according to the setting of PP-03.(One Menu
mode by default)
3.2 Viewing and Modifying Function Codes
The operation panel of the PE6000 adopts three-level menu.
The three-level menu consists of function code group (Level I), function code (Level II), and
function code setting value (level III), as shown in the following figure.