7.Digital Operator
Status display mode
7-4
7.4
Status display mode
In this mode, the state of driver and the display of the alarm number when alarm occurring can be
checked. In addition to these, reset of alarm, the software version check of driver, and setup of a
password can be performed at the time of an alarm number display.
1) Driver status display
Marking
Description
Status code
Control power supply established.
Control power supply (r, t) is established and driver ready
(RDY) is ON.
0
Main circuit power supply established.
Main power supply (R, S, and T) is established, but
operation preparation completion signal is OFF.
2
Magnetic Pole Position Estimation Ready (blinking)
Main power supply (R, S, T) is established and Magnetic
Pole Position Estimation Ready is on.
9
Magnetic Pole Position Estimation
Rotates after displaying the character "O" (upper half).
9
Operation setup completion signal established.
(continuous)
Magnetic pole position estimation is completed, and
Operation setup completion signal is on.
4
Servo is ON.
Rotates after displaying the character
“
8
”
.
8
2) Over-travel status display
Marking
Description
Over-travel status at CW rotation.
Over-travel status at CCW rotation.
3) Status display of regenerative overload warning, and overload warning
Marking
Description
Regenerative overload Warning status.
If operation is kept on, alarm may be issued.
Overload Warning status
If operation is kept on, alarm may be issued.
4) Alarm code and driver status code when alarm occurs
Marking
Description
Please take a measure according to the contents of
"Maintenance" when alarm occurs.
Status code
Alarm code