5.Operation
Group 8 control system settings
5-60
■
By combining with Group9, Condition Settings for Enabling Functions, the functions of Group9 are
valid for ID42 to ID47.
Selection
Contents
12
LOWV_IN
Function is valid while in low speed status (speed is lower
than the LOWV Setting Value)
13
LOWV_OUT
Function is valid while not in low speed status (speed is
lower than the LOWV Setting Value)
14
VA_IN
Function is valid while in speed attainment status (speed is
higher than the VA Setting Value)
15
VA_OUT
Function is valid while not in speed attainment status (speed
is higher than the VA Setting Value)
16
VCMP_IN
Function is valid while in speed matching status
(within command-actual velocity consistent range).
17
VCMP_OUT
Function is valid while not in speed matching status
(within command-actual velocity consistent range).
18
ZV_IN
Function is valid while in zero speed status (speed is lower
than the ZV Setting Value)
19
ZV_OUT
Function is valid while not in zero speed status (speed is
lower than the ZV Setting Value)
✔
Speed Matched Range is based on
“
Group8 ID45, ID47
”
setup.
◆
Example: The driver sets the GAIN1 and GAIN2 switching without using input signal
from the host unit.
Set 15: VA_OUT to Group9 ID13 Gain Switching Condition 1 GC1.
Set 00: Always_Disable to Group9 ID14 Gain Switching Condition 2 GC2.
Set 50min
-1
(arbitrary value) to Group8 ID44 Speed Attainment
(High Speed setting) VA.
GAIN2 is valid while
[VA] is below the
setting value.
VA setting value : 50min
-1
Velocity
VA_OUT
VA_OUT
VA_IN
GAIN1 is valid while [VA] is higher than
the setting value.
GAIN2 is valid while
[VA] is below the
setting value.
Summary of Contents for M-EGA-15A2301
Page 149: ...No Text on This Page ...
Page 237: ......