7.Digital Operator
Parameter edition
7-10
13
“
GrC.04
”
is displayed.
14
WR
Hold down WR for over a second.
15
MODE
“
Gr nu
”
is displayed.
16
WR
Hold down WR for over a second.
17
Display to be switched, and then rightmost LED flashes.
The set data are displayed. The display left shows
“
1
”
as
nu is set first.
18
Display the figure
“
2 (numerator)
”
you want to set by
addition/ subtraction, cursor button.
19
WR
Hold down WR for over a second.
20
When display flashes 3 times, and then the flashing
stops, the setting is completed.
If the set value is out of the setting range, the set value in
the step 13 is displayed without flashing 3 times.
21
MODE
Press MODE.
22
Display to be switched to the display left.
✔
There are three setting ranges of pulse frequency dividing,
“
1/1 to 1/64,
”
“
2/3 to 2/64,
”
and
“
1/32768 to 32767/32768.
”
If you set the figure out of the ranges, the figure is not displayed, the figure before the
setting flashes.
When setting numerator, the figure of denominator is applicable to the figure presently
established.
For example, to change from
1
/1 to 2/64, you need to set the denominator first, as the
numerator is already fixed to
“
1,
”
and
“
2
/1
”
is out of the ranges.
✔
“
nu
”
stands for numerator,
“
dE
”
stands for denominator.