5.Operation
Group 8 control system settings
5-52
ID
Contents
19
Deviation Clear Selection
[CLRSEL]
Setting range
Unit
Standard value
00 to 03
-
00:Type1
■
Sets ON/OFF of position deviation clear during servo OFF, and deviation clear signal treatment.
◆
Selects operation during servo OFF. Deviation clear/ Deviation NOT clear
◆
Selects deviation signal treatment. Level detection /Edge detection
◆
Select proper setting corresponding to above combination from the list below.
Selection
Contents
00
Type1
When Servo OFF
Clear
Deviation
Deviation Clear Input =
Level Detection
During servo OFF,
Deviation clear is always
executed. While Deviation
clear input is ON,
Deviation clear is always
executed.
01
Type2
When Servo OFF
Clear
Deviation
Deviation Clear Input =
Edge Detection
At the edge of OFF
ON of
Deviation clear input, Deviation
clear is executed.
02
Type3
When Servo OFF
NOT Clear
Deviation
Deviation Clear Input =
Level Detection
During servo OFF, Deviation
clear is not executed.
(After servo ON, the motor may
operate suddenly.)
03
Type4
When Servo OFF
NOT Clear
Deviation
Deviation Clear Input =
Edge Detection
During servo OFF, Deviation
clear is not executed.
(After servo ON, the motor may
operate suddenly.)