5.Operation
System parameters list, confirmation and settings
5-3
2) System parameters list
System parameters list is shown below. Settings vary depending on the system used.
Please confirm 3), 4) and the following IDs for the proper settings.
ID
Contents
00
Control Cycle
01
Main Circuit Power Input Type
02
Regenerative Resistor Selection
05
Serial Encoder Resolution
0A
Position Control Selection
3) Confirmation and settings of system parameters
Use the setup software or digital operator, to set the specifications the driver. For operating
instructions, see [Digital Operator (7)] for the Digital Operator.
System Parameters Setting (driver)
ID
Contents
00
Control Cycle
■
Select the control cycle for Velocity control/ Torque control.
“
High Frequency Sampling
”
enables increasing the frequency response of the velocity control
system. Please set at
“
00: Standard_Sampling
”
for normal use.
Selection
Contents
00
Standard_Sampling
Standard Sampling
01
High-freq_Sampling
High Frequency Sampling
■
“
High frequency sampling mode
”
is not available for the following conditions:
◆
System Parameters ID0A setting value of the
“
Position Control Selection
”
Present setting value
Contents
01:Model1
Model Following Control
or
Present setting value
Contents
02:Model2
Model Following Vibration Suppressor Control