5.Operation
Operation sequence (power off during operation)
5-16
4) Sequence when power is turned OFF during operation (During servo ON)
Holding brake engage
Command acceptance prohibition
Motor free
BONDLY = 300msec
Motor stop
Control source OFF
Main power supply OFF
Power ON output OFF
Dynamic brake ON
S-RDY S-RDY2
Control source
Power ON signal
Main circuit power
Servo ON signal
Dynamic brake signal
Motor velocity
Holding brake excitation signal
Command acceptance permission signal
Motor excitation signal
Operation setup completion signal
(Input)
(Output)
(Output)
(Output)
(Output)
(Output)
(Output)