5.Operation
Monitor function
5-19
Refer to the following charts for the display format of ID01 to 05 as setup software and Digital Operator
have different indicators:
■
Display of the setup software
Bit
7
6
5
4
3
2
1
0
0 or 1
0/1
0/1
0/1
0/1
0/1
0/1
0/1
0/1
■
Display of the Digital operator
Bit
7
6
5
4
3
2
1
0
ON
OFF
-
LED4
LED3
LED2
LED1
Digital operator at the front of the Driver
ID
Contents
06
Velocity monitor [VMON]
■
Displays the rotation speed of the motor.
Display range
Unit
-9999 to 9999
min
-1
07
Velocity command monitor [VCMON]
■
Displays the velocity command value.
Display range
Unit
-9999 to 9999
min-1
08
Torque monitor [TMON]
■
Displays the output torque.
Display range
Unit
-499.9 to 499.9
%
09
Torque command monitor [TCMON]
■
Displays the torque command value.
Display range
Unit
-499.9 to 499.9
%
0A
Position deviation monitor [PMON]
■
Displays the position deviation value.
◆
Setup software displays values in decimal notation.
Display range
Unit
-2147483648 to 2147483647
Pulse
◆
Digital operator displays values in hexadecimal notation.
ID
Data range
Display range
Unit
0A
Bit31 to Bit0
H.FFFF to L.0000
Pulse