5.Operation
Group 9 Function enabling condition settings
5-62
Group9 List of selection contents
■
Keeping the function always valid or invalid
Selection
Contents
00
Always_Disable
Function is always invalid
01
Always_Enable
Function is always valid
■
Using function with the generic input signals
Selection
Contents
02
CONT1_ON
Function is valid when generic input, CONT1, is ON
03
CONT1_OFF Function is valid when generic input, CONT1, is OFF
04
CONT2_ON
Function is valid when generic input, CONT2, is ON
05
CONT2_OFF Function is valid when generic input, CONT2, is OFF
06
CONT3_ON
Function is valid when generic input, CONT3, is ON
07
CONT3_OFF Function is valid when generic input, CONT3, is OFF
08
CONT4_ON
Function is valid when generic input, CONT4, is ON
09
CONT4_OFF Function is valid when generic input, CONT4, is OFF
0A
CONT5_ON
Function is valid when generic input, CONT5, is ON
0B
CONT5_OFF Function is valid when generic input, CONT5, is OFF
0C
CONT6_ON
Function is valid when generic input, CONT6, is ON
0D
CONT6_OFF Function is valid when generic input, CONT6, is OFF
0E
CONT7_ON
Function is valid when generic input, CONT7, is ON
0F
CONT7_OFF Function is valid when generic input, CONT7, is OFF
10
CONT8_ON
Function is valid when generic input, CONT8, is ON
11
CONT8_OFF Function is valid when generic input, CONT8, is OFF
■
Activating the functions conditioning the rotational speed of motor
Selection
Contents
12
LOWV_IN
Function is valid while in low speed status
(speed is lower than the LOWV Setting Value)
13
LOWV_OUT
Function is valid while not in low speed status
(speed is lower than the LOWV Setting Value)
14
VA_IN
Function is valid while in speed attainment status
(speed is higher than the VA Setting Value)
15
VA_OUT
Function is valid while not in speed attainment status
(speed is higher than the VA Setting Value)
16
VCMP_IN
Function is valid while in speed matching status
(within command-actual velocity consistent range).
17
VCMP_OUT
Function is valid while not in speed matching status
(within command-actual velocity consistent range).
18
ZV_IN
Function is valid while in zero speed status
(speed is lower than the ZV Setting Value)
19
ZV_OUT
Function is valid while not in zero speed status
(speed is lower than the ZV Setting Value)