5.Operation
Group A General output terminal output condition
/ Monitor output selection/ Serial communication settings
5-71
ID
Contents
13
Analog Monitor Output Polarity
[MONPOL]
Setting range
Unit
Standard value
00 to 08
-
00:MON1+_MON2+
■
Select Output polarity of Analog monitor output, MON1and MON2
◆
For both MON1 and MON2, set from any of the followings:
+ No Polarity Rotation,- Polarity Rotation, ABS Absolute Value Output
Selection
Contents
00:MON1+_MON2+
MON1: Output positive voltage at CW Rotation.
Output positive/negative voltage.
MON2: Output positive voltage at CW Rotation.
Output positive/negative voltage.
01:MON1-_MON2+
MON1: Output negative voltage at CW Rotation.
Output positive/negative voltage.
MON2: Output positive voltage at CW Rotation.
Output positive/negative voltage.
02:MON1+_MON2-
MON1: Output positive voltage at CW Rotation.
Output positive/negative voltage.
MON2: Output negative voltage at CW Rotation.
Output positive/negative voltage.
03:MON1-_MON2-
MON1: Output negative voltage at CW Rotation.
Output positive/negative voltage.
MON2: Output negative voltage at CW Rotation.
Output positive/negative voltage.
04:MON1A
MON1: Output positive voltage at CW and CCW
Rotation.
MON2: Output negative voltage at CW Rotation.
Output positive/negative voltage.
05:MON1ABS_MON2-
MON1: Output positive voltage at CW and CCW
Rotation.
MON2: Output negative voltage at CW Rotation.
Output positive/negative voltage.
06:MON1+_MON2ABS
MON1: Output positive voltage at CW Rotation.
Output positive/negative voltage.
MON2: Output positive voltage at CW and CCW
Rotation.
07:MON1-_MON2ABS
MON1: Output negative voltage at CW Rotation.
Output positive/negative voltage.
MON2: Output positive voltage at CW and CCW
Rotation.
08:MON1ABS_MON2ABS
MON1: Output positive voltage at CW and
CCWRotation.
MON2: Output positive voltage at CW and CCW
Rotation.
Summary of Contents for M-EGA-15A2301