7.Digital Operator
Status display mode
7-7
8) How to set pass ward
The function that can be used by setting up a password from digital operator can be restricted, and
change of a parameter etc. can be forbidden. The function and the setting method can be used is
the following.
Step
Displayed
character,
number, code
Input
button
How to operate
1
Make the state of driver, or the state where alarm is displayed.
2
Push addition button for more than 1 second.
3
Display switches as the left and the whole display blinks.
When setup of the password has ended, display does not blink.
4
WR
Push WR for more than 1 second.
5
Display changes as the left and right end LED blinks.
6
Display arbitrary numerical values with addition and subtraction
and the cursor button.
0000 and FFFF cannot be set up.
7
WR
Push WR for more than 1 second.
8
Display blinks 3 times, and setup will be completed if blink
stops.
9
MODE
Push MODE once.
10
Returns to Process 1.
11
Password will become effective if power supply is turned on
again.
9) How to cancel password
Step
Displayed
character,
number, code
Input
button
How to operate
3
Display switches as the left and the whole display lights up.
Password is not set up when the display is blinking.
4
WR
Push WR for more than 1 second.
5
Display switches as the left and right end LED blinks.
6
Set up password is displayed with addition and subtraction and
the cursor button.
7
WR
Push WR for more than 1 second.
8
Display blinks 3 times, and cancel will be completed if blink
stops.
9
MODE
Push MODE once. Then returns to Process 1.
10
After cancel does not need to turn on power supply again.
Status display
Test Operation
(JOG operation is possible)
Alarm history display
Monitor display