7.Digital Operator
Fixed monitor display, setting motor code of driver to be used
7-17
7.14 Fixed monitor display
The display shows monitoring value in a second after powering up.
It shows monitoring value set at [Group A ID30: Monitor Display Selection [MONDISP]] in status
display mode.
“
Monitor
”
to be displayed is the same as parameter ID in monitor display mode, but in the setting
value
“
00 STATUS driver status monitor
”
, the display will be different from the code display in the
monitor mode and will show the driver status in the status display mode (- or
≡
).
In the state of alarm occurring, requiring safety function input, requiring motor magnetic pole
detection or detecting the poles, the monitor display prioritize these status over the fixed display.
In case of setting
“
Group A ID30: Monitor Display Selection [MONDISP]
”
from SETUP software with
the digital operator in
“
Status mode
”
, either reboot the hardware or push
“
MODE
”
button on the
digital operator to show
“
Status mode
”
again.
7.15 Motor code-setting of motor used
Step
Displayed
character,
number, code
Input
button
How to operate
1
MODE
Push MODE until it displays the left.
2
Display changes and right end LED blinks.
3
WR
Push WR for more than 1 second.
4
Display the motor cord of the motor used with addition and
subtraction and the cursor button.
5
WR
Push WR for more than 1 second.
6
A display change as the left and it performs.
7
Changes to the display of the left after a normal end.
8
Turn on the power supply again.
Note)
The motor that cannot be combined or used displays the left in Process 5.
In this display, please set up by "Setup Software."
Applicable
“
Motor
”
varies depending on the
“
Software Version
”
for the
“
Driver.
”
Summary of Contents for M-EGA-15A2301
Page 149: ...No Text on This Page ...