3.Installation
Driver
3
-
3
I
I
3)
Mounting direction and location
✔
Refer to optional parts, Appendix, for metal fittings for front mounting.
4)
Control arrangement within the machine
■
Leave at least 50 [mm] space above and below the driver to ensure unobstructed airflow from the inside
of the driver and the radiator. If heat gets trapped around the driver, use a cooling fan to create airflow.
■
Make sure the temperature around the driver does not exceed 55[°C]. For longevity and reliability
purposes it is recommended to keep the temperature below 40[°C].
■
Leave at least 10 [mm] space on both sides of the driver to ensure unobstructed airflow from the heat
sinks on the side and from the inside of the driver.
■
If the driver is installed on its side, make sure that the ambient temperature does not exceed 50[°C], and
mount the back panel to a metal plate.
✔
Recommended metal plate thickness is 2[mm] or more
■
Since M
-
EGA
-
30A2301 is equipped with ventilation fan on its side, installation of driver as shown below is
recommended.
In the case of front-mounting
Ventilation
M4
M4
Front mounting
In the case of rear
-
mounting
M4
M4
I
50mm or more
50mm or more
10mm or
more
10mm or
more
10mm or
more
Driver
Fan
Side view
Venti
50mm or more
50mm or more
Front view