background image

CDC-0252-1-ACB

 

instructions

Standard version 

"

-R“ 

Mirrored version (option "-L")

Please order bracket sets separately 

Summary of Contents for CDC-0252-1-ACB Series

Page 1: ...CDC 0252 1 ACB instructions Standard version R Mirrored version option L Please order bracket sets separately ...

Page 2: ... reduced motor speed in ventilation mode SHEV high speed function fast running feature in case of an alarm Protection system for the main closing edge Rated voltage and Bus signals loopable for max 3 drives Connection possible from both sides The force can be increased at the factory up to 400 N nominal current 1 A in the seal area Relief of pressure on window gasket after closing Direct connectio...

Page 3: ...ng Ingress protection Temp range Fire stability Ambient humidity Emission sound pressure level Additional functions approx 1500 N 10 000 double strokes 30 S6 EN 60034 1 Aluminium powdercoated RAL 9006 IP 32 5 75 C 30 min 300 C 90 not condensing LpA 35 dB A Closing edge protection activated 3 repetitions of stroke Locking relief activated retraction lift max 0 2 mm Main closing edge Beside closing ...

Page 4: ...guration with perfect position directly from the control panel In this process all status messages such as the OPEN and CLOSED signals opening stroke and drive errors are transmitted to the control panel BSY synchronised electronics A synchronous group can contain up to 8 drives which communicate via bus Each drive has its own address configurable with SCS The last drive of a synchronous group is ...

Page 5: ...signatory Technical Director 11 08 2016 Maintenance and cleaning Maintenance work is only allowed when the device is in a de energized condition Inspection and maintenance has to be carried out according to D H maintenance notes Only original D H spare parts may be used RepairistobecarriedoutexclusivelybyD H Wipe away debris or contamination with a dry soft cloth Donotusecleaningagentsorsolvents G...

Page 6: ...Speed High Speed High Speed Mot a Mot b 1 2 3 4 5 L 6 N 7 Z A E X a b LT Group MOT BK BK OG 2x47kW End mod ul Term inal mod ule Mod ule term inal EM 47 K WH BN OG YE GN GY Mot a Mot b ACB a HS BSY a BSY b ACB b CDC 0252 1 Junction box Master 2 2 up to max 3 drives looped through WH BN OG YE GN GY Mot a Mot b ACB a HS BSY a BSY b ACB b CDC 0252 1 Slave 1 Mot b BN Mot a WH 24 V DC 24 V DC Monitoring...

Page 7: ...b BSY b ACB b ACB b CDC 0252 1 CDC 0252 1 Junction box Master 2 Slave 1 High Speed High Speed High Speed WH white BN brown OG orange YE yellow GN green PK pink GY grey Monitoring Not in case of GVL E K M Protect wire against short circuit In case of connection to D H SHEV control panels with E HS line monitoring Cable according to D H table for layout of cables See instructions for use of control ...

Page 8: ...tion SKS BN Mot b OG SKS GY SKS GN BSY b YE BSY a WH Mot a BN Mot b OG ACB a HS GY ACB b GN BSY b YE BSY a WH Mot a Motor side Chain side Type plate WH white BN brown OG orange YE yellow GN green PK pink GY grey Dyer Environmental Controls Ltd Unit 10 Lawnhurst Trading Estate Cheadle Heath Stockport SK3 0SD Tel 44 0 161 491 4840 E Mail enquiry dyerenvironmental co uk www dyerenvironmental co uk ...

Reviews: