NOVA electronics Inc. MCX514 -
84
-
84
-
// Synchronous action SYNC1 setting
WR6
←
0185h Write
// D3
~
D0 0101 PREV3
~
0
:
Activation factor Finish constant speed driving
// D8
~
D4 11000 ACT4
~
0
:
Action termination of split pulse
// D15 0 REP
:
Repeat must be disabled
WR0
←
0127h Write
// SYNC0,1 Enable
WR0
←
0183h Write
// Start driving
WR0
←
0150h Write
// Starts relative position driving