// Synchronous action setting
// Synchronous action SYNC0 setting
WR6
←
0171h Write
// D3
~
D0 0001 PREV3
~
0
:
Activation factor MRm object changed to True
// D8
~
D4 10111 ACT4
~
0
:
Action start of split pulse
WR0
←
0126h Write
// Synchronous action SYNC1 setting
WR6
←
0201h Write
// D3
~
D0 0001 PREV3
~
0
:
Activation factor MRm object changed to True
// D8
~
D4 00000 ACT4
~
0
:
Action NOP
// D11
~
D9 001 SNC+3,2,1
:
Other SYNC Activation Activate SNC+1
WR0
←
0127h Write
// Synchronous action SYNC2 setting
WR6
←
0030h Write
// D3
~
D0 0001 PREV3
~
0
:
Activation factor NOP
// D8
~
D4 00011 ACT4
~
0
:
Action Load MRm
→
SP1
// D11
~
D9 001 SNC+3,2,1
:
Other SYNC Activation Activate SNC+1
WR0
←
0127h Write
// SYNC2
~
0 Enable
WR0
←
0187h Write
// Start driving
WR0
←
0150h Write
// Starts relative position driving
In this case, if split pulse is set to output at the timing of position 4,999, it actually starts to output from positon 5,000.
[Note]
•
In this case, while operating split pulse, the user must use caution with changing a split length and pulse width by such
as a synchronous action. Because split pulses around the change may cause unexpected behavior due to the timing of
change.