NOVA electronics Inc. MCX514 -
75
-
75
-
// SYNC0,1 Enable
WR0
←
0183h Write
// Start driving
WR0
←
0152h Write
// Starts
+
direction continuous pulse driving
SYNC1 is activated and interrupt occurs
// Read timer value saved in MR1
WR0
←
0135h Write
RR6
→
Read
RR7
→
Read
// Timer-stop
WR0
←
0174h Write