104
Module installation and connection
Procedure steps
Step
Action
1
Turn on and configure the terminal or a communications port on
the PC using the parameters in the following table.
See the PC or terminal user manual for instructions.
Parameter
Value
Baud rate
9600
Data bits
8
Stop bits
1
Parity
None
2
Insert the 9-pin receptacle end of the console cable into the
console connector on the 8691 SF/CPU or 8692 SF/CPU
module, or to the maintenance port of the WSM.
3
Attach the 9-pin plug end of the cable to the serial
communications port on the back of the PC or terminal.
--End--
Connecting a modem to the SF/CPU
Use an AT or Hayes-compatible modem and serial cable to provide remote
dial-in access to the CLI.
Procedure steps
Step
Action
1
Turn on and configure the modem, using the parameters in the
following table.
See the modem documentation for instructions.
Setting
Value
Clear to send (CTS) signal
On
Data terminal ready (DTR)
signal
Modem can only connect if the DTR
signal is present. If the DTR signal is
not present, the modem disconnects.
Data carrier detect (DCD) or
received line signal detection
(RLSD)
On while the carrier is present. The
switch uses DCD to detect modem
connect and disconnect.
Data set ready (DSR) signal
On
Ready to send (RTS) signal
Ignored
Nortel Ethernet Routing Switch 8600
Installation — Modules
NN46205-304
02.02
Standard
16 June 2008
Copyright © 2008 Nortel Networks
.