10. Specifications
PROGRAMMABLE AC/DC POWER SOURCE
238
10.18 Sequence
Effective only for AC-INT, AC+DC-INT, and DC-INT.
KP3000GS
Number of memories
5 (non-volatile)
Number of steps
Maximum 255 (for each sequence)
Setting range of Step
Time
0.0010 s to 999.9999 s
Intra-Step behavior
Constant, Keep, Linear Sweep
Parameter
*32
Output range
AC/DC mode (The signal source is fixed to INT)
(The above 2 items are common within one sequence)
AC voltage, frequency, waveform
DC voltage
Start Phase
Stop Phase
Step termination
Jump count (1 to 9999, or infinite)
Specification of the Jump-to step
Synchronous step output (2bit)
Specification of the branch step
Trigger output
Sequence control
Start
Stop
Hold
Resume
Branch 1, Branch 2
*32: For DC-INT, the AC voltage, frequency, waveform, Start Phase, and Stop Phase cannot be set.