4.16 Setting Voltage using External DC Input Signal
KP3000GS
153
Operation Method
1.
Enter the ACDC mode or the DC mode. Following two methods are available.
(a)
Shortcut operation:
+
Every time you press the keys, the mode is switched to AC, ACDC, and DC in this order.
(b)
Press the [Osc] soft-key and select [1:AC/DC]. From the opened menu, select [2: ACDC] or
[3: DC].
2.
Set the output DC voltage in the [DCV] item.
4.16 Setting Voltage using External DC Input Signal
In the AC-VCA mode, you can use the external DC input signal to set the AC output voltage of the
internal signal source. In the DC-VCA mode, you can use the external DC input signal to set the DC
output voltage of the internal signal source. The external DC signal is input to this product through
the external signal input connector. When the signal source is VCA, the specifications except the
output voltage setting are same as when the signal source is INT.