4.2 Using Sequence Function
KP3000GS
61
Step Behavior (Const, Keep, Sweep)
For the intra-Step parameter other than waveforms and phases, the following three patterns can be
set as the method to change values in the step.
Constant (Const)
Fixed to the value set in the step.
Keep
Keeping the value immediately before transitioning to the step. That is, the value is changed
depending on the status of the previous step. Although the parameter value can be set even if
the operation type setting is Keep, the parameter setting value is ignored when sequence is
executed.
Sweep
It changes linearly from the value immediately before transitioning to the value set in the step,
taking the Step Times. In other words, it reaches the setting value after the Step Time passes in
the step. The starting value is changed depending on the status of the previous step.
Previous step
Next step
Previous step
Next step
Previous step
Next step
Used as the setting
value in the next step
Keeps the final value
of the previous step
Changes from the final value of
the previous step to the setting
value of the next step
Cons
t
Keep
Sweep
Setting
value
Setting
value
Figure 4-2 Step Behavior
--------
Notes
------------------------------------------------------------------------------------------------------------
The Step Behavior for the waveform and phase is always Constant (Const).
The rate of crest factor/clip ratio cannot be changed though a clipped sine wave can be selected
as an output waveform in Sequence function. Set these parameters beforehand using
Continuous function.
Sequence function displays the measured value in Sequence function, which is equivalent to
that of the Continuous function. However, harmonic current measurement (see
4.4
) cannot be
displayed.
-----------------------------------------------------------------------------------------------------------------------------
Step Behavior
Summary of Contents for KP3000GS
Page 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000GS INSTRUCTION MANUAL...
Page 2: ......
Page 3: ...DA00033845 005 PROGRAMMABLE AC DC POWER SOURCE KP3000GS INSTRUCTION MANUAL...
Page 4: ......
Page 5: ......
Page 19: ......
Page 20: ...KP3000GS 1 1 Outline 1 1 Overview 2 1 2 Features 2...
Page 23: ......
Page 197: ......
Page 207: ......
Page 219: ......
Page 243: ......
Page 275: ......
Page 277: ......
Page 278: ......