4. Advanced Operation
PROGRAMMABLE AC/DC POWER SOURCE
62
4.2.2 Parameters of Sequence Function
Table 4-2 shows the parameters of Sequence function. The common parameters are common to one
sequence. In Sequence function, signal source is fixed to INT. In each step, set the step-control
parameter and the intra-Step parameter. As for intra-Step parameter, the item and range that can be
set differ depending on the output range (100 V/200 V range) and output mode
(AC-INT/ACDC-INT/DC-INT) as in the case of Continuous function. This section describes
intra-Step parameters and step-control parameters separately.
Table 4-2 Parameters of Sequence Function
Common
parameter
Step-control parameter
Intra-Step parameter
Output range
AC/DC mode
Step Time
Jump-to step
Jump count (1 to 9999, or infinite)
Branch step
Step termination
Step sync code output (2bit)
Start Phase
Stop Phase
Trigger output
Frequency
Waveform
AC voltage
DC voltage
Frequency (Freq), waveform (Wave), AC voltage (ACV), DC voltage (DCV)
The setting for the output of each step. Phase angle can also be set per step.
Step Time (Step Time)
Set the output time of that step. Unit can be selected from [s] or [ms].
Jump-to step (Jump To)
When selected, the destination step of the jump at the end of the step can be specified. By specifying
the Jump count ([Jump Cnt]), you can set up a loop to repeat the same step. After jumping for the
times specified for one sequence, the action at the end of step follows the step termination setting.
If Jump-to is set to off, the action at the end of step follows the step termination setting.
--------
Notes
------------------------------------------------------------------------------------------------------------
When the step termination is set as [Hold], the hold status is enabled before the jump.
-----------------------------------------------------------------------------------------------------------------------------
Summary of Contents for KP3000GS
Page 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000GS INSTRUCTION MANUAL...
Page 2: ......
Page 3: ...DA00033845 005 PROGRAMMABLE AC DC POWER SOURCE KP3000GS INSTRUCTION MANUAL...
Page 4: ......
Page 5: ......
Page 19: ......
Page 20: ...KP3000GS 1 1 Outline 1 1 Overview 2 1 2 Features 2...
Page 23: ......
Page 197: ......
Page 207: ......
Page 219: ......
Page 243: ......
Page 275: ......
Page 277: ......
Page 278: ......