4. Advanced Operation
PROGRAMMABLE AC/DC POWER SOURCE
124
4.
Move the cursor to [Close], then press the ENTER key. The arbitrary waveform setting window
closes.
5.
Set the frequency and output voltage. Turn on the output. Set the arbitrary waveform output
voltage in the [ACV] item using Peak-to-Peak value.
--------
Notes
------------------------------------------------------------------------------------------------------------
ACV is the setting relative to the full scale amplitude of the arbitrary waveform data. When
the arbitrary waveform data amplitude is not at full scale, the output voltage amplitude
becomes smaller than the ACV setting.
-----------------------------------------------------------------------------------------------------------------------------
4.8
Using Memory Function
Using the Memory function, you can access this product's internal memory and USB memory to
save, load, clear, and rename the basic setting, arbitrary waveform, sequence, and simulation.
Opening the Memory View
1.
Press the MENU key to move to the root menu, then select [Memory] (or press the MEMORY
key on the Continuous function screen).