4.4 Measuring Harmonic Current
KP3000GS
113
4.4.2 Basics
Harmonic current measurement function is available only for the Continuous function, AC-INT, and
set frequency of 50 Hz or 60 Hz.
The harmonic current components up to order 40 are displayed as the RMS and a percentage to
fundamental wave component.
--------
Notes
------------------------------------------------------------------------------------------------------------
The Harmonic current measurement function does not support the standard tests defined by
organizations such as IEC. Use this function for a preliminary testing.
-----------------------------------------------------------------------------------------------------------------------------
4.4.3 Measured Value Display Method
Operation procedure
1.
In the Continuous function, select the [Measure] soft-key
[4: Harmonic].
2.
The view opens populated with the measured harmonic components of order 1 to 10.