10.19 Simulation
KP3000GS
239
10.19 Simulation
This allows you to simulate power line abnormalities, such as blackout, voltage rise, voltage drop,
abrupt phase change, and abrupt frequency change. It can be used only for AC, sine wave, and
AC+DC-INT. Note that it does not support IEC or other standards test.
KP3000GS
Number of memories
5 (non-volatile)
Number of steps
6 (Initial, Normal 1, Trans 1, Abnormal, Trans 2, Normal 2)
Setting range of Step
Time
0.0010 s to 999.9999 s (0 s is available only for the Transition Step)
Parameter Output
range
(The above item is common within the Simulation)
AC voltage
Frequency
Waveform (sine wave only)
Start Phase (excluding the Transition Step)
Stop Phase (excluding the Transition Step)
Synchronous step output (2bit)
Trigger output
Repeat count (1 to 9999 times or infinite)