6.1 Overview
6
-
2
FRA 51602
6.1 Overview
This instrument can save measurement data, measurement conditions, and screen capture data to files
located on a USB memory device that is connected to the USB port on the front panel of the instrument.
The data in the measurement data files and measurement conditions files can be read and used by your
instrument or other
FRA 51602
instruments. The data can also be read by personal computers such as IBM
PC/AT compatible machines.
The formats for the parameters contained in the measurement data files and measurement conditions files
are listed in the following table.
【
Parameter formats
】
Symbol
Format
Example
(NR1)
Integer (numerical value)
123
(NR2)
Decimal point notation without exponent
(numerical value)
0.075
(NR3)
Decimal point notation with exponent
(numerical value)
4.99E+06
(CRD)
Text
ALL
(SRD)
Text enclosed in double quote marks
"No error"
{CRD1|CRD2|..}
Any one of text or CRD1, 2, ...
{ON|OFF}
(bool)
Boolean value
ON, OFF, 1, 0
6.2 Measurement data file format
The measurement data file is in text format (CSV) and can be used by text editors or spreadsheet software,
etc. The file timestamp indicates the time at which the data was obtained by measurement, not the time the
file was saved.
The structure of the measurement data file depends on whether or not the data was obtained by sequence
measurement.
Beginning of file
Header
Measurement
conditions
Measurement
data
Measurement data
RAW[0]
RAW[1]
RAW[2]
:
End of file
RAW[n-1]
Figure 6-1
Structure of the measurement data file (no sequence measurement)
Summary of Contents for FRA51602
Page 1: ...NF Corporation GAIN PHASE ANALYZER FRA51602 INSTRUCTION MANUAL OPERATIONS...
Page 2: ......
Page 3: ...GAIN PHASE ANALYZER FRA51602 INSTRUCTION MANUAL OPERATIONS DA00061635 001...
Page 24: ...1 3 Operating principles 1 10 FRA51602 Blank...
Page 31: ...2 2 Installation 2 7 FRA51602 Figure 2 1 Rack mounting kit assembly diagram JIS...
Page 32: ...2 2 Installation 2 8 FRA51602 Figure 2 2 Rack mounting kit assembly diagram EIA...
Page 33: ...2 2 Installation 2 9 FRA51602 Figure 2 3 Rack mounting kit dimensions JIS...
Page 34: ...2 2 Installation 2 10 FRA51602 Figure 2 4 Rack mounting kit dimensions EIA...
Page 130: ...3 6 Initial settings 3 92 FRA51602 Blank...
Page 264: ...9 9 Miscellaneous specifications 9 18 FRA51602 Figure 9 3 External dimensions...
Page 280: ...XVI FRA51602 Blank...
Page 282: ......
Page 284: ......
Page 285: ......
Page 286: ...http www nfcorp co jp NF Corporation 6 3 20 TsunashimaHigashi Kohoku ku Yokohama223 8508JAPAN...