NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 561
Off-Hook Alarm
O-6
Service Conditions (cont’d)
13.
If a station belongs to the node that has an Attendant Console, the station is connected with the Attendant
Console. If a station belongs to the node that does not have an Attendant Console, the station is connected
with the specified Attendant Console in the remote node according to the system data assigned. See the
figure below.
Interactions
1.
A total of seven OFF-HOOK ALARM Groups per tenant may be assigned to the system, if the termination
point is a station. Any station not assigned in ASGD will go to reorder tone after the Register Prepause
timer (ASYD, System Data 1, Index 128) expires. If the termination point is the Attendant Console, all
stations in the tenant will terminate to the Attendant Console.
2.
ASAT cannot be used to construct different OFF-HOOK ALARM groups terminating to specific
Attendant Consoles. If the tenant is equipped with more than one Attendant Console, OFF-HOOK
ALARM calls will be directed to all consoles with OFF-HOOK ALARM keys programmed in AAKP.
3.
The following features will function on terminating calls to a predetermined station:
CALL PICKUP
[C-7]
CALL TRANSFER
[C-11]
CALL HOLD
[C-6]
CALL FORWARDING
[C-5A]
4.
No tone is provided on CALL WAITING-TERMINATING [C-12].
Programming
STEP 1:
ASYD
- System Data 1, Index 128, Bits 0-3. Register Prepause timer is used for OFF-HOOK
ALARM. After the register times out, the station assigned to an OFF-HOOK ALARM group will ring
at the terminating Attendant Console or station. Leave Index 128 as 00H for normal operation.
System Data 1, Index 168, Bit 4. Enable OFF-HOOK ALARM? 0/1: No/Yes.
System Data 1, Index 168, Bit 5. Is the terminating point for OFF-HOOK ALARM an Attendant
Console or station? 0/1: Attendant Console/Station. If Attendant Console is chosen, go to AAKP
command. If station is chosen, go to the ASID and ASGD commands.
STEP 2:
ASID
- This command defines the purpose of this Special Incoming Group, and is used in conjunction
with ASGD. Assign the following:
TN:
Tenant Number
F:
Function Number (0-7)
0:
OFF-HOOK ALARM
GN:
Group Number (1-7).
S/A:
Special Incoming Equipment
Node A
Node B
Node B
Attendant Console A
FCCS Link
Station A has been set
to be connected with
the Attendant Console
A by system data.