NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 809
Automatic Recall - CCIS
A-71
Interactions (cont’d)
5.
The station will continue to ring, even as the call recalls to the Attendant Console. When conference is
allowed and a conference card is programmed and installed, if the station should answer at the same time
the Attendant answers the recalling call, a three-way conversation will then take place. The Attendant can
press the SRC, DEST, or TALK keys to achieve the desired conversation, or press the RELEASE key to
get out of the conversation.
6.
Station calls extended by the Attendant to another station within the same system (node) will recall to the
Attendant. Station calls extended by the Attendant over CCIS will not recall. Trunk calls will recall in both
instances.
Programming
STEP 1:
ASYD
- System Data 1, Index 145.
Timer Class 1 = 2 seconds. For normal operation, assign 00H. [RAM data is 94H.] Any call that uses
AUTOMATIC RECALL, keeps one of the Attendant Console switched loops busy. Since there are six
loops per Attendant Console, the maximum use of this feature is limited to that number.
AUTOMATIC RECALL interval (normally set for 30 seconds) is a system option (System Data 1,
Index 145), and can be varied from two seconds to two minutes in increments of two seconds.
System Data 1, Index 73, Bit 6. Is the dialed number display for AUTOMATIC RECALL in service?
0/1: No/Yes.
System Data 2, Index 2, Bit 5.
Must be programmed as data “1”. Attendant Loop Release in service.