NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 501
Multiple Call Forwarding - Don’t Answer
M-25
Interactions
1.
If access codes for CALL FORWARDING-BUSY LINE [C-2] and CALL FORWARDING-DON’T
ANSWER [C-3] are the same, only one key needs to be assigned in AKYD or ADSL, and only one access
code needs to be assigned in ASPA.
2.
Any UCD station is allowed to activate CALL FORWARDING-DON’T ANSWER [C-3]. When this
station sets CALL FORWARDING-DON’T ANSWER [C-3], calls directed to this station through UCD
hunting or directly-dialed will ring and then follow the destination of the CALL FORWARDING-DON’T
ANSWER [C-3].
3.
CALL FORWARDING-DON’T ANSWER [C-3] to an Attendant Console will not operate when the
system is in Night mode. If ATTENDANT NIGHT TRANSFER [A-19] is provided, the call is forwarded
to the night transfer station.
4.
If the CALL FORWARDING-DON’T ANSWER [C-3] target station is a D
term
with DO NOT DISTURB
[D-21D] activated, call forwarding is not activated. The forwarding station will ring beyond the timer set
in ASYD, System Data 1, Index 139.
5.
When the CALL FORWARDING-DON’T ANSWER [C-3] feature is set from Station A to Station B, if
Station A is idle and Station B is busy, Station A will ring beyond the timer set in ASYD, System Data 1,
Index 139.
6.
When a call is call forwarded, the destination station is recorded for STATION MESSAGE DETAIL
RECORDING [S-10].
Programming
STEP 1:
ASYD
- System Data 1, Index 5, Bit 0. Access codes for CALL FORWARDING-BUSY LINE [C-2]
and CALL FORWARDING-DON’T ANSWER [C-3] are same or separate? 0/1: Same/Separate.
System Data 1, Index 69, Bit 2. Is a short tone set to alert person receiving the call that this is a CALL
FORWARDING-DON’T ANSWER [C-3] call? 0/1: No/Yes.
System Data 1, Index 69, Bit 7. MULTIPLE CALL FORWARDING-BUSY [M-24], -ALL CALLS
[M-44], in service? 0/1: No/Yes.
System Data 1, Index 139. Assign the No-Answer timer for station-to-station, DID and TIE Line calls.
For 30 seconds, assign 00H (RAM data is 3FH).
System Data 1, Index 141. Assign the No Answer timer for incoming calls via the Attendant Console.
It will then be forwarded to the next station according to the System Data 1, Index 145 timer. For 10
seconds, assign 00H. (RAM data is 35H.)
System Data 2, Index 6, Bit 2. Enable CALL FORWARDING-DON’T ANSWER [C-3] on a per-
tenant basis.
System Data 2, Index 6, Bit 7. Enable CALL FORWARDING-DON’T ANSWER [C-3] via Attendant
Console.
STEP 2:
ANPD
- Reserve a number level for feature access and cancel. Assign for Normal (N), Hooking (H),
and Busy (B). Assign NND in accordance with a predetermined numbering plan.
STEP 3:
ASPA
- Assign an access code to CALL FORWARDING-DON’T ANSWER [C-3] entry, SID = 12
and to CALL FORWARDING-DON’T ANSWER [C-3] cancel SID = 13. Assign Connection Status
Index (CI) for Normal (N) service.
STEP 4:
ASFC
- Assign the stations to activate CALL FORWARDING-DON’T ANSWER [C-3] a Service
Feature Class that allows SFI = 8.
STEP 5:
AKYD
- For D
term
sets, CALL FORWARDING-ALL CALLS [C-5] may be assigned to a
programmable line/feature key. Assign Type:Function:CALL FORWARD-DON’T ANSWER [22].