NEAX2400 IPX Feature Programming Manual
Page 874
NDA-24297, Issue 1
C-58
Consultation Hold - All Calls - CCIS
Programming
ASYD
- System Data 1, Index 156. Trunk Soft Hold Timer A, used with second dial tone trunks.
Assign data 00H for 30 seconds. (Data 31H may be used for a value of two seconds if CALL
TRANSFER-ALL CALLS [C-50] is to be used immediately after connecting to the trunk.) This is the
time between trunk connections when switch hook flash is allowed on a non-senderized trunk
connection.
System Data 1, Index 157. Trunk Soft Hold Timer A, used with senderized trunks. Assign data 00H for
a value of 18 seconds. (Data 31H may be used for a value of 2 seconds if CALL TRANSFER-ALL
CALLS [C-50] is to be used immediately after connecting to the trunk.) This is the time between trunk
connection and when switch hook flash is allowed on a senderized trunk connection. It is also used to
determine when SMDR billing will begin.
System Data 2, Index 1, bits 0 & 1. CONSULTATION HOLD allowed or denied. 00: Denied; 01:
Originating and Terminating Calls allowed, Tandem Call Denied; 11: All calls allowed. Normally
assign data “11”.
System Data 3, Index 2, bits 0-3. Switch hook flash begin timer. To calculate this value: (1-FH) x 120
msec = Timer.
System Data 3, Index 2, bits 4-7. Switch hook flash end timer. To calculate this value: (1-FH) x 120
msec = Timer. For both begin and end timers, assign 91H for 120-1080 msec.
f (t)
0 ms
Bit 0-3
120 ms
No Detection
Bit 4-7
1080 ms Disconnection