NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 89
Brokerage - Hotline
B-6
Service Conditions (cont’d)
•
the destination station is off-hook.
•
the destination station is already engaged in a three-party call.
c.) the destination is the Attendant or is connected to an outside party.
16.
When EXECUTIVE RIGHT-OF-WAY [E-1, E-1D] is used with this feature, it is not activated under any
of the following conditions:
• when utilizing EXECUTIVE RIGHT-OF-WAY [E-1, E-1D] service using switch hook flash and
access code.
• when all three-party conference trunks are busy.
• when the destination is not in the two-party connection (an incoming call is in the middle of terminating
to the destination or the destination places a call on hold or the destination is in off-hook status or the
three-party connection including the destination has already been established).
• when the destination is connected with the Attendant Console or the C.O. trunk.
17.
This feature can be activated via FCCS.
18.
Only the station assigned a telephone number is available for the station assignment when activating this
feature via FCCS.
19.
The station, the Attendant Console/Desk Console (operator call), and the trunk can be a destination for
Hotline.
20.
When Call Forwarding - All Calls/Busy Line/Don’t Answer service has been set to the called station, these
features are available for the call to the station.
21.
When a calling party encounters a busy station, the call may bridge into the connection, depending on the
data assigned by the ASYD command.
Programming
STEP 1:
ASDT
- Assign to a PA-16LC circuit the following data:
TN:
Tenant Number
STN:
Station Number
LENS: Line Equipment Number (6 digits) - Actual LENS for TEC 14, Virtual LENS for TEC 18
TEC:
Telephone Class (1-31)
1:
DP (10pps)
2:
PB
3:
DP/PB
12:
D
term
13:
Data terminal via D
term
14:
HOTLINE
15:
CAS Line
18:
Virtual Circuit
RSC:
Route Restriction class (0-15)
SFC:
Service Feature Class (0-15)
STEP 2:
AHLS
- Assign the station numbers programmed above for the following parameters:
HOT TN:
Hotline Tenant
STN:
Hotline Station
TYPE:
1 = station
CON TN:
Connecting Station’s Tenant
CON STN:
Connecting Station Number