NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 51
Announcement Service - Attendant
A-59
Programming (cont’d)
STEP 6:
MBTK
- Assign the Make Idle status to the announcement trunk.
STEP 7:
ARRC
- If TIE Line, DID, or REMOTE ACCESS TO PBX [R-2] connection to the Announcement
Service trunk is required, allow trunk-to-trunk connection using ARI-D-RES=1 (Direct Connection is
allowed.)
STEP 8:
AAED
- This command is used to assign announcement equipment.
Dead Level:
Assign:
TN:
Tenant Number
EQP:
(Announcement Equipment Number) = 0 (Dead Level). For example, level 8 is not assigned
an announcement is returned rather than a reorder tone.
RT, TK:Route and Trunk number of the trunk connected to the announcement equipment.
Unused Number:
Assign:
TN:
Tenant Number
EQP:
1 (Unused Number). For example: EXT-7836 is not in the system; an Announcement is
returned rather than a reorder tone.
RT, TK:Route and Trunk number of the trunk connected to the announcement equipment.
Announcement Service:
Assign:
TN:
Tenant Number
EQP:
= 2 - 15
RT, TK:Route and Trunk number of the trunk connected to the announcement equipment.
C:
Duration of Connection, 0/1:Disconnection occurs in 30 seconds / Connection is held until the
station releases. See the requirements of the application for the announcement equipment. For
Dead Level applications, data 0 is assigned.
R:
Sending RBT 0/1: sending RBT/not sending RBT.
A:
Answer Signal Sending, 0/1: no answer from Incoming trunk/Answer from Incoming trunk.
Normally assign data “1”.
M:
Multiple Connection 0/1: Single Connection/Multiple Connection. Assign usually for single
connection.
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ALRTN
- This data must be assigned to the NCN.
Assign the logical route number to the physical route.
STEP 2:
AAEDN
- This data must be assigned to the NCN.
Assign the announcement equipment data.
UGN: User Group Number