NEAX2400 IPX Feature Programming Manual
Page 400
NDA-24297, Issue 1
I-9
Intercom Calling
Interactions (cont’d)
Numbering Consists of the following:
30-39
Stations in Group Calling would dial only two digits to reach other members of the group.
2.
All My-line STATION-TO-STATION CALLING [S-11] capabilities such as VOICE CALL-D
term
[V-
2D], MESSAGE REMINDER-D
term
[M-19D], CALL BACK [C-1], etc. are denied because INTERCOM
CALLING uses a virtual circuit sub-line appearance.
3.
An incoming Intercom Call will be provided with distinctive three-burst ringing.
4.
An intercom station is only allowed to call other intercom stations. If a non-intercom station attempts a
call, reorder tone is heard, and the LCD displays:
5.
An intercom station cannot call the Attendant Console.
Programming
STEP 1:
ANPD
- Reserve a number level for feature access. Assign Connection Indexes, CI = N, H, B; Normal
(N), Hooking (H), and Busy (B) (applicable to any service feature assigned to this level).
Assign NND in accordance with a predetermined numbering plan.
STEP 2:
ASPA
- Two access codes must be assigned for this feature.
Assign the Tenant and the Access Code (ACC). For Individual Speed Calling-Assign, assign a
Connection Index of Normal (N). For SRV = SSC (Service Code), assign SID 14 (Speed Calling -
Station;Entry).
For Individual Speed Calling-Access, assign the Tenant and Access Code (ACC). Assign a Connection
Index of Normal (N). For SRV = SSC (Service Code), assign SID 21.
STEP 3:
ASFC
- Construct a Service Feature Class that allows SFI 19 and 70. Assign this SFC to the stations
that act as INTERCOM CALLING extension numbers. SFI 70 is only used on virtual lines in their
own SFC.
STEP 4:
ASDT
- Program the stations within a group as a virtual line (TEC = 18). Determine LENs from
available time slots in the system.
TN:
Tenant Number
STN:
Station Number
LENS: Line Equipment Number (6 digits)
TEC:
Telephone Class (1-31)
1: DP (10pps)
2: PB
3: DP/PB
12: D
term
13: Data terminal Via D
term
14: Hotline
15: CAS Line
16: Data Terminal Via Data Module
18: Virtual Circuit
23: ISDN Terminal
REST
(Time Display)