NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 47
Account Code - Attendant
A-52
Programming (cont’d)
For example:
44 - 623423 - 511234 - 617 - 555 - 2323
2
+
0
+
6
=
8
ACC
+
AUTH CODE
+
ACCT CODE
=
NND
STEP 4:
ASFC
- For stations to use ACCOUNT CODE, assign a Class of Service that allows SFI 27.
STEP 5:
AMND
- If Authorization Codes are used with ACCOUNT CODES, then for Tenant 0, assign the
Destination Code (DC) as the first digit of all Authorization Codes and the Maximum Necessary Digits
(MND) of the Authorization Codes. For the above example, a DC of six is assigned with an MND of
six.
STEP 6:
AATC
- Assign when Authorization Code is used.
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
Note
STEP 1:
ANPDL
- Reserve a number level for service feature access. Assign Connection Index, CI = N, H, B;
Normal, Hooking, and Busy (applicable to any service feature assigned to this level). Assign NND in
accordance with a predetermined numbering plan.
STEP 2:
ASPAL
- For SRV = SSC (Service Code), SID = 41, assign the access code. Assign the number of
digits in the ASPAL service feature access code plus the number of digits that will appear in the
ACCOUNT
CODE
for
the
NND
parameter.
When
ACCOUNT
CODE
operates
with
AUTHORIZATION CODE [A-20], the above assignment is omitted. In ASPAL, assign for SRV =
SSC (Service Code), SID = 42.
The NND value will include the number of digits in the ASPAL service feature access code plus the
number of digits that appear in the ACCOUNT CODE.
Note:
When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required
in addition to ASYDL or ASYDN.