STEP 1:
ASYD
- System Data 2, Index 1, Bit 7. Does TOLL RESTRICTION apply to SPEED CALLING-
SYSTEM [S-3]? 0/1: Yes/No. If TOLL RESTRICTION applies, construct an RSC that will allow the
station access to the outgoing number.
STEP 2:
ASFC
- Construct a Service Feature Class that allows Service Feature Index (SFI) 12; SPEED
CALLING-SYSTEM [S-3]. Assign this SFC to the Hotline station.
If using a Virtual Circuit (TEC = 18) for the hotline, SFI: 36 (Special Common Battery/Hotline) must
be set to “1” for the Virtual Circuit’s SFC.
STEP 3:
ASDT
- Assign the HOTLINE-OUTSIDE station as a TEC = 18, Virtual Circuit or TEC = 14, Hotline.
TN:
Tenant Number
STN:
Station Number
LENS: Line Equipment Number (6 digits)
TEC:
Telephone Class (1-31)
1: DP (10pps)
2: PB
3: DP/PB
12: D
term
13: Data terminal Via D
term
14: HOTLINE
15: CAS Line
18: Virtual Circuit
23: ISDN Terminal
27: Eight Conference Equipment
RSC:
Route Restriction Class (0-15)
For assignment of RSC, ARSC command.
SFC:
Service Feature Class (0-15)
For assignment of SFC, ASFC command.
STEP 4:
ASPD
- Assign the Tenant Number, the Abbreviated Digit Code-ADC, and the CD-Telephone
Number to be sent. Include in the CD the access code of the route.
STEP 5:
AHLS
- Assign the HOTLINE-OUTSIDE station with the following parameters:
HOT TN:
HOTLINE-OUTSIDE Tenant
STN:
HOTLINE-OUTSIDE Station
TYPE:
2 (ADC)
CON TN:
Connecting Stations Tenant. Assign same TN # as in HOT TN:
ADC:
Abbreviated Digit Code of Corresponding Outside Number.