NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 49
All Zone Paging
A-53
Interactions (cont’d)
8.
ALL-ZONE PAGING is not possible from CONSULTATION HOLD [C-17].
9.
CALL HOLD [C-6]: A Paging trunk cannot be placed on Call Hold.
10.
The D
term
LCD display indicates BUSY when the Paging trunk is Busy. Reorder tone is returned.
11.
If Priority Page is to be used with ALL-ZONE PAGING in ARTD, CDN 6:TCL must be assigned as Data
8, Page with ringback tone. SYS1, Index 73 affects the operation of Page routes assigned Page with
ringback tone. Therefore, if the Priority Page is used with ALL-ZONE PAGING, then MEET-ME
PAGING [M-1, 11] and PAGING TRANSFER [P-10] are not available to the system.
12.
Priority Page access will not disconnect an Attendant Console engaged in a Paging trunk connection.
Programming
STEP 1:
ASYD
- System Data 1, Index 73, Bits 0 & 1. For the Page function only, assign Data 00.
STEP 2:
ARTD
- Assign the Paging route as shown below:
RT:1
1-OSGS
:2
2-ONSG
:3
5-TF
:1
6-TCL
:8
7 L/T
:1
8-RLP
:2
15-LSG
:1
STEP 3:
ATRK
- Assign the LEN Number, Paging trunk, Route Number, Trunk Number, and Tenant Number.
STEP 4:
MBTK
- Assign the Make Idle status to the Paging Trunks.
STEP 5:
ANPD
- Assign a level for trunk access. Assign Connection Index, CI = Normal (N), Hooking (H).
Assign the number of necessary digits, according to a predetermined numbering plan. Busy Lamp
Field is not activated.
STEP 6:
ASPA
- Assign Paging Trunk route data for two or more routes, with a maximum of seven. (CI = N,
SRV = OGCA (Outgoing Call [Advance]), COUNT = 2 ~ 7, RT = Paging trunk route).
STEP 7:
ARSC
- Assign to the station, which is allowed access to Paging trunks, a Route Restriction Class
(RSC) that is allowed these routes in Route Restriction Index (RRI) 2 & 3.
FCCS Programming
No unique programming is required for the FCCS network.