NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 987
Message Center Interface - CCIS
M-67
Programming (cont’d)
System 1, Index 78, Bit 1: (1) Calling and Intermediate Station number indication. Bit 1: (1) Kind of
service class indication.
System 1, Index 116 (Port 0) through Index 123 (Port 7): Assign the kind of terminal = 1: printer/MCI
to the corresponding output port. (Assigned via AIOC.)
System 2, Index 6, Bit 0: MCI service when terminating UCD group in this Tenant. 0/1 = Out/In
Service.
System 2, Index 7, Bit 1: MCI service when terminating the Attendant in this tenant. 0/1 = Out/In
Service.
STEP 2:
AIOC
- Assign the function and attribute data of the IOC ports.
STEP 3:
ASFC
- Allows MWL Control (SFI = 74) to the SFC of the station. SFI = 74: MW lamp setting-station
(Called Party).
STEP 4:
ARPC
- Assigns the Remote Point Code data for the Message Center.
FCCS Programming
Set the data for the Centralized MAT following programming of CENTRALIZED MAINTENANCE -
CCIS
and telephone number (maximum of 8 digits) following NUMBER PORTABILITY -
CCIS
See the manual of the NEAX2000 IVS
2
for the data programming at the NEAX2000 IVS
2
.
STEP 1:
ASYD
- System Data 1, Index 246, b3. Maximum number of digits for Station Number field in MCI
text format. 0/1 = 6 digits/8 digits