NEAX2400 IPX Feature Programming Manual
Page 256
NDA-24297, Issue 1
C-151
Call Return
Service Conditions (cont’d)
8.
Service Conditions for Automatic Saving with the access code:
a.) This service is available for the telephone corresponding with Caller-ID service. Equips Caller ID
function or the telephone using Caller ID adapter.
b.) This service is not available when a call is terminated to an ISDN terminal or a PS terminal.
c.) The last calling number is stored in the data memory.
d.) Even when the office data makes Analog Caller ID station effective by ASFC, SFI 146=1,
received numbers are saved (calling number is saved for the trunk receiving the number and
calling station number is saved for the station call).
e.) Operating procedure with the access code is effective for call origination to the stored number's
party.
f.) When originating a call via the access code from the D
term
, the LCD displays the dialed number
and does not display stored number.
g.) Even if the LC card is initialized, saved calling number is not deleted.
h.) The latest calling number is saved in the data memory even when CALL RETURN is not
available according to the ASFC. SFI 155=0. Accordingly, the office data is changed later, call
origination using the number saved when the service is restricted is available.
9.
Service Conditions for Manual Saving:
a.) Manual Saving is available for the D
term
with the Save and Repeat key.
b.) This service is available when a D
term
is in communication with the terminating trunk.
c.) When the calling number is saved, “S&R” and the first 12 digits are displayed on the D
term
LCD.
d.) When the circuit card listed in item 1-b is not used, the first 6 digits of the received number
are saved.
e.) Call origination can be made to the stored number while dial tone is heard. After seizing a trunk,
this feature is not available.
f.) For more information, refer to SAVE AND REPEAT - D
term
Programming
STEP 1:
ASYD
- System Data 1, Index 80, bit 1. 0/1 = #/* key is used to delete the stored calling number.
System Data 1, Index 322, bit 7. 0 = Call Return is not available for station-to-station calling. 1 = Call
Return is available for station-to-station calling.
Note:
Also, for an incoming call from CCIS line, this data is required.
STEP 2:
ASPA/ASPAL/ASPAN
- When originating a call to the saved number using the access code, assign
the access code for this service.
SRV:
SSCA
SIDA: 106 (Call Return)
STEP 3:
ASFC
- When using the access code for this service, assign Service Feature Class that allows SFI 155
(Call Return) to the stations activating this service.
STEP 4:
AKYD
- Assign Call Return key when using Automatic Saving function.
KYI: 1
FKY: 118 (Call Return)
Assign Save and Repeat key when using Manual Saving function.
KYI: 1
FKY: 7 (Save and Repeat)
FCCS Programming
No unique programming is required for the FCCS network.