Troubleshooting 8-9
Error
code
Error message
Recommended Action
02D1
System Memory exceeds the CPU's caching
limit.
02F4
EISA CMOS not write able.
02F5
DMA Test Failed.
02F6
Software NMI Failed.
02F7
Fail-safe Timer NMI Failed.
Contact your service representative.
0611
IDE configuration changed
0612
IDE configuration error - device disabled
Check IDE configuration.
0613
Com A configuration changed
0614
Com A config. error - device disabled
Check COM A configuration.
0615
Com B configuration changed
0616
Com B config. error - device disabled
Check COM B configuration.
0B22
Processors are installed out of order.
Request the maintenance to replace the
CPU.
0B28
Unsupported Processor detected on
Processor 1.
0B29
Unsupported Processor detected on
Processor 2.
Make sure that the server supports the
CPU. If you are not sure, contact your
service representative to request the
maintenance.
0B30
FAN1 Alarm occurred.
0B31
FAN2 Alarm occurred.
0B32
FAN3 Alarm occurred.
0B33
FAN4 Alarm occurred.
0B34
FAN5 Alarm occurred.
0B35
FAN6 Alarm occurred.
0B36
FAN7 Alarm occurred.
0B37
FAN8 Alarm occurred.
0B38
FAN9 Alarm occurred.
0B39
FAN10 Alarm occurred.
0B3A
FAN11 Alarm occurred.
0B3B
FAN12 Alarm occurred.
0B3C
FAN13 Alarm occurred.
0B3D
FAN14 Alarm occurred.
0B3E
FAN15 Alarm occurred.
Clean the internal cooling fans.
Contact your service representative to
replace the fan.
0B42
Resource Conflict
0B43
Warning: IRQ not configured
0B45
System configuration Data Write Error
Contact your service representative.
0B50
Processor #1 with error taken off line.
0B51
Processor #2 with error taken off line.
0B5F
Forced to use Processor with error
Because an error is detected in CPU, the
system is forcibly started. Contact your
service representative.
0B60
DIMM group #1 has been disabled
0B61
DIMM group #2 has been disabled
0B62
DIMM group #3 has been disabled
0B63
DIMM group #4 has been disabled
0B64
DIMM group #5 has been disabled
0B65
DIMM group #6 has been disabled
Contact your service representative.
0B6F
DIMM group with error is enabled
0B70
The error occurred during temperature
sensor reading.
Contact your service representative.
Summary of Contents for N8100-14522F
Page 16: ...x This page is intentionally left blank...
Page 122: ...4 54 Configuring Your Server This page is intentionally left blank...
Page 178: ...6 22 Installing and Using Utilities This page is intentionally left blank...
Page 190: ...7 12 Maintenance This page is intentionally left blank...
Page 254: ...A 2 Specifications This page is intentionally left blank...
Page 262: ...C 2 IRQ This page is intentionally left blank...
Page 316: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 320: ...G 4 Product Configuration Record Table This page is intentionally left blank...