8-28 Troubleshooting
Problems with RAID System and RAID Controller
Check the following if the server configuring a RAID System does not operate properly or a
management utility does not operate correctly. If a relevant item is found, follow the processing
method.
Fail to install the OS:
T
Is the RAID Controller configured?
→
Provide proper configuration for the RAID Controller by using the LSI Software
RAID Configuration Utility.
Fail to start the OS:
T
Is the BIOS of the RAID Controller changed?
→
Set the BIOS correctly by using the LSI Software RAID Configuration Utility.
T
Does POST recognize the RAID Controller?
→
After making sure that the RAID Controller is connected correctly, then power on
the server.
If the RAID Controller is not recognized correctly despite correct connection, the
RAID Controller may be failed. Contact your service representative.
Rebuild fails:
T
Is the capacity of the hard disk drive to be rebuilt sufficient?
→
The hard disk drive to be rebuilt should have the same capacity of the failed had
disk drive.
T
Is RAID0 configured?
→
RAID0 has no data redundancy, therefore, Rebuild is disabled in the RAID0
configuration. Replace the failed hard disk drive, create the configuration data
again and initialize the hard disk drives. Then recover the data by using backup
data.
Auto rebuild fails:
T
Was a sufficient time taken for hot swap of hard disk drives?
→
To allow the auto rebuild to operate correctly, it should take 90 seconds or longer
for the interval between the removal of the failed hard disk drive and the
installation of a new hard disk drive.
T
Is configuration correct?
→
Check the setting of auto rebuild by using the LSI Software RAID Configuration
Utility. <Menus to check: Top menu - [Objects] - [Adapter] - [Auto Rebuild]>
* Auto Rebuild cannot be specified in WebBIOS.
Summary of Contents for N8100-14522F
Page 16: ...x This page is intentionally left blank...
Page 122: ...4 54 Configuring Your Server This page is intentionally left blank...
Page 178: ...6 22 Installing and Using Utilities This page is intentionally left blank...
Page 190: ...7 12 Maintenance This page is intentionally left blank...
Page 254: ...A 2 Specifications This page is intentionally left blank...
Page 262: ...C 2 IRQ This page is intentionally left blank...
Page 316: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 320: ...G 4 Product Configuration Record Table This page is intentionally left blank...